Contents Summary of Automatic Aging Function Additional Manual
Page 1AUTOMATIC AGING fuji FUNCTION 1. Outline This function executes aging automatically according to OFF time (period) of oscillator or the laser gas condition of inner oscillator(vacuum system). Applied software is as follows. FS16i-LA B8F1-18 B8F3-06 FS16i-LB B8H1-02 (Add on 05th Ed.) Power command an
Page 2fuji (1) Automatic Aging After setting of parameters, aging below is automatically executed. - Number of aging is automatically set based on terminated time of oscillator at the last HV OFF. - If OFF time is less than Minimum OFF time(PRM15339), automatic aging is not executed - Automatic aging is s
Page 3fuji Note) When laser alarm No.4073, which means that a laser gas bottle becomes empty, occurs during purge operation, two times aging function is executed automatically at next time of laser start-up. This function is available with the software as follows. FS16i-LA B8F1-17, B8F3-05 FS16i-LB B8H1-0
Page 45. Number of aging (Rev. on 03rd Ed) Number of aging is automatically set according to OFF time. But according to setting value of minimum OFF time PRM15339, that number is different below. ① Minimum OFF time is between 30H and 83H OFF TIME NUMBER OF AGING 0H≦ OFF TIME < MINIMUM OFF TIME 0 MINIMUM O
Page 56. Parameter (Add Model on 03rd Ed) #7 #6 #5 #4 #3 #2 #1 #0 15008 EGE EGE This bit sets “enable” and “disable” of Automatic Aging function 1: enable 0: disable 15320 Power command for power calibration( This is enable at EGE=1) Power command to get power calibration efficiency When automatic aging f
Page 615323 Calibration time for power calibration (This is enable at EGE=1) Time of power command to get power calibration efficiency Unit : Sec Setting range : 0 - 32767 Standard setting : 180: C1000-E, C1500B, C2000B, C2000C, C2000-E 300: C3000C, C3000D, C4000A, C4000-E, C6000A,C6000B 15324 Tube pressu
Page 715326 Power command for aging (This is enable at EGE=1) Power command in executing aging with automatic aging Unit : W Setting range : 0 - 7000 Standard setting : 700: C1000-E 1000: C1500B 1500: C2000B,C2000C,C2000-E 2000: C3000C,C3000D,C6000A 2500: C4000A, C4000-E 4000: C6000B 15327 Pulse frequency
Page 815330 Tube pressure for power calibration(50Hz)(This is enable at EGE=1) Setting value of gas pressure for power calibration This is the same as PRM15331 for oscillator installed inverter. (This is setting value for oscillator not installed inverter in the area of 50Hz.) Unit : 0.1Torr Setting range
Page 915333 Pulse duty for power calibration and aging Pulse duty command for power calibration Unit : % Setting range : 0 - 100 Standard setting : 100 15334 Number of aging(This is enable at EGE=1) Times to execute aging sequence. This parameter (0,2 – 7) is automatically set according to OFF time when a
Page 10(Add on 03rd Ed) 15339 Minimum OFF time (This parameter is enable at EGE=1) OFF time for executing of automatic aging. Unit : HOUR Setting range : 30 - 120 Standard setting : 60 When setting value is less than 30, it is considered that 60 is set. When setting value is larger than 120 or equals 120,