04 03.05.13
TSUGESHITA
CORRESPONDENCE TO CALENDAR
03 03.05.13
TSUGESHITA
ADD MIN.OFFTIME, PMC PRAMETER
06 04.09.08
TOKITO
ADD. FOR ALM.4073
05 03.12.24
SUZUKI
ADD.APPLIED SOFTWARE AND EDIT.
EDIT. DATE DESIG. DESCRIPTION APPRO.
FANUC LTD 004/10
TITLE
A-81053E-053
SHEET
AUTOMATIC AGING FUNCTION
DRAW. No.
5. Number of aging
Number of aging is automatically set according to OFF time. But according to setting value of
minimum OFF time PRM15339, that number is different below.
① Minimum OFF time is between 30H and 83H
0H≦ OFF TIME < MINIMUM OFF TIME 0
MINIMUM OFF TIME ≦ OFF TIME < 83H 2
84H ≦ OFF TIME ≦107H 3
108H≦ OFF TIME ≦131H 4
132H≦ OFF TIME ≦155H 5
156H≦ OFF TIME ≦179H 6
180H≦ OFF TIME 7
② Minimum OFF time is between 84H and 107H
0H≦ OFF TIME < MINIMUM OFF TIME 0
MINIMUM OFF TIME ≦ OFF TIME ≦107H 3
108H≦ OFF TIME ≦131H 4
132H≦ OFF TIME ≦155H 5
156H≦ OFF TIME ≦179H 6
180H≦ OFF TIME 7
③ Minimum OFF time is between 108H and 120H
0H≦ OFF TIME < MINIMUM OFF TIME 0
MINIMUM OFF TIME ≦ OFF TIME ≦131H 4
132H≦ OFF TIME ≦155H 5
156H≦ OFF TIME ≦179H 6
180H≦ OFF TIME 7
The calculation of OFF time corresponds to calendar.
(Rev. on 03rd Ed)
(Add on 04th Ed)