15330 Tube pressure for power calibration(50Hz)(This is enable at EGE=1)
Setting value of gas pressure for power calibration
This is the same as PRM15331 for oscillator installed inverter.
(This is setting value for oscillator not installed inverter in the area of 50Hz.)
Unit : 0.1Torr
Setting range : 0 - 32767
Standard setting : 470: C6000A, C6000B
500: C1000-E
560: C1500B, C2000C, C2000-E
590: C2000B
600: C3000C
630: C4000A, C4000-E
670: C3000D
15331 Tube pressure for aging(60Hz)(This is enable at EGE=1)
Setting value of gas pressure for aging
(This is setting value for oscillator installed and not installed inverter in the area of 60Hz)
Unit : 0.1Torr
Setting range : 0 – 32767
Standard setting : 470: C6000A,C6000B
560: C1500B,C2000C, C2000-E
590: C2000B
600: C3000C
630: C4000A, C4000-E
670: C3000D
15332 Pulse frequency for power calibration and aging
Pulse frequency command for power calibration
Unit : Hz
Setting range : 5 – 2000
Standard setting : 100
Note) Please set (values of PRM15242,
15243)-100 into PRM15330, 15331,
because gas pressure is sometimes
Note) Please set (values of PRM15242,
15243)-100 into PRM15330, 15331,
because gas pressure is sometimes