FANUC LTD 007/10
15326 Power command for aging (This is enable at EGE=1)
Power command in executing aging with automatic aging
Unit : W
Setting range : 0 - 7000
Standard setting : 700: C1000-E
1000: C1500B
1500: C2000B,C2000C,C2000-E
2000: C3000C,C3000D,C6000A
2500: C4000A, C4000-E
4000: C6000B
15327 Pulse frequency command for aging(This is enable at EGE=1)
Pulse frequency command in executing aging with automatic aging
Unit : Hz
Setting range : 5 - 2000
Standard setting : 100
15328 Pulse duty command for aging (This is enable at EGE=1)
Pulse duty command in executing aging with automatic aging
Unit : %
Setting range : 0 - 100
Standard setting : 30:C6000A, C6000B
50:C1500B, C2000B, C2000C, C2000-E,C3000C, C3000D, C4000A
C4000-E
15329 Calibration time for aging (This is enable at EGE=1)
Time to execute every aging
Unit : Sec
Setting range : 0 – 32767
Standard setting : 900