Machine Operator's Panel Interface Unit (with 3-MPG interfaces) A-73282E/01 Additional Manual Page 2

Additional Manual
-Item-
1. OVERVIEW
2. SPECIFICATION No.
3. CONNECTION
3.1 System Configuration
3.2 Signal Assignment
3.3 Interface for MPG
3.4 PMC Addresses
3.5 Dimension Diagram (Including Connector Locations)
4. Other notices
4.1 Address Allocation
4.2 Applicable system and software
Machine Operator's Panel
Interface Unit
with 3 MPG interfaces
Connection Manual
EDIT.
FANUC LTD
SHEET
DRAW. NO.
CUST.
TITLE
001/6
DESCRIPTIONDESIG.DATE
01 98.04.13 Aizawa
Machine Operator's Panel Interface
Unit (with 3-MPG Interfaces)
Connection Manual
A-73282E/01

Contents Summary of Machine Operator's Panel Interface Unit (with 3-MPG interfaces) A-73282E/01 Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) No.TMN98/068E Date 1998.May.6 General Manager of Hardware Laboratory Machine Operator's Panel Interface Unit (with 3-MPG interfaces) 1. Communicate this report to: ○ Your information ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON Machine tool builder Sales agen
  • Page 2Machine Operator's Panel Interface Unit (with 3 MPG interfaces) Connection Manual -Item- 1. OVERVIEW 2. SPECIFICATION No. 3. CONNECTION 3.1 System Configuration 3.2 Signal Assignment 3.3 Interface for MPG 3.4 PMC Addresses 3.5 Dimension Diagram (Including Connector Locations) 4. Other notices 4.1 Ad
  • Page 3.OVERVIEW 1. The machine operator's panel interface unit with 3-MPG interfaces has been newly released. This manual describes the 3-MPG interfaces only. The other interfaces are identical to the existing unit. .SPECIFICATION No. 2. Specification note A16B-2201-0110 Existing unit :with one MPG interf
  • Page 43-2.Signal Assignment Connector pin signal assignment JA3(Connector on the manual pulse generator) 10 20 +5V 9 +5V 19 8 18 +5V 7 17 6 HB3 16 0V 5 HA3 15 4 HB2 14 0V 3 HA2 13 2 HB1 12 0V 1 HA1 11 Reference(The Other MG interface connectors) CA40 CNB1 14 DI37 01 +5V 01 LM 05 EON 09 HA1 08 DI31 15 0V 0
  • Page 53-3.Interface for MPG Machine operator's panel Interface unit Manual pulse generators JA3 Manual pulse generator #1 01 HA1 11 (M3screw terminal) 02 HB1 12 0V +5V 0V HA1 HB1 03 HA2 13 04 HB2 14 0V Manual pulse generator #2 05 HA3 15 (M3screw terminal) 06 HB3 16 0V +5V 0V HA2 HB2 07 17 Manual pulse ge
  • Page 6Scope in which PMC 3-4.PMC Addresses addresses can be used PMC BIT NUMBER I/O Link allocation ADDRES 7 6 5 4 3 2 1 0 128/128 256/256 DI+00 FUSE DI+01 KY07 KY06 KY05 KY04 KY03 KY02 KY01 KY00 DI+02 KY17 KY16 KY15 KY14 KY13 KY12 KY11 KY10 DI+03 KY27 KY26 KY25 KY24 KY23 KY22 KY21 KY20 DI+04 KY37 KY36 KY
  • Page 73-5.Dimension Diagram (Including Connector Locations) 4..Other notices 4-1. Address Allocation Allocation name of this unit is as follows. Allocation name PMC address Note 1) Remarks OC02I (16byte) DI+00~DI+15 1 MPG interface can be used OC03I (32byte) DI+00~DI+21 3 MPG interfaces can be used CM15I