1.
..
.OVERVIEW
The machine operator's panel interface unit with 3-MPG interfaces has been newly
released. This manual describes the 3-MPG interfaces only. The other interfaces are
identical to the existing unit.
2.
..
.SPECIFICATION No.
Specification note
A16B-2201-0110 Existing unit :with one MPG interface
A16B-2201-0115 New released unit :with 3-MPG interfaces
3.
..
.CONNECTION
3-1.System Configuration
EDIT.
SHEET
DRAW. NO. CUST.
TITLE
002/
DESCRIPTIONDESIG.DATE
A-73282E/01
Other machine
interface
CNC
FANUC
I/O Link
Power supply
unit
Note1
Machine operator's
panel interface unit
JD1A
(I/O Link)
JD1B
CPD1
CA40
JA3
MPG
+
General
DI/DO
MPG
3 units
Note2
CM26
CM15
CM16
CM17
CNB1
CNA1
Machine Operator's
panel
Matrix DI/DO
*ESP,OTR,
General purpose
DI/DO
LM/SM
Power ON/OFF
(MPG)
Power magnetic
cabinet
*ESP,OTR
Input unit
Power ON/OFF
Spindle amp.
LM/SM
*ESP :Emergency stop signal
OTR :OT release signal
ON/OFF :Power ON/OFF control signal
LM/SM :Load meter or speed meter signal
MPG :Manual pulse generator
CRT/
MDI
Note 1
Power requirements
When 60% of the DI/DO points are on, this interface unit requires "1.0A".
Note 2
Cable length: Maximum 30cm.