Machine Operator's Panel Interface Unit (with 3-MPG interfaces) A-73282E/01 Additional Manual Page 5

Additional Manual
3-3.Interface for MPG
EDIT.
FANUC LTD
SHEET
DRAW. NO. CUST.
TITLE
004/
DESCRIPTIONDESIG.DATE
A-73282E/01
JA3
Machine operator's panel
Interface unit
0V+5V HB1H
A
1
Manual pulse generator #1
(
M3screw terminal
)
Manual pulse generators
0V+5V HB
HA
0V+5V HB
3
HA
3
Cable connection
HA1
HB1
+5V
0V
1
2
9
12
7Red
7White
5Red
2Black
HA1
HB1
+5V
0V
Terminal block
Manual pulse
generators
HA1
HB1
+5V
0V
#1
Ground
plate
Shield
Cable Wire
01 HA1
02 HB1
03 HA2
04 HB2
05 HA3
06 HB3
07
08
09 +5V
10
11
12 0V
13
14 0V
15
16 0V
17
18 +5V
19
20 +5V
HA2
HB2
+5V
0V
3
4
18
14
8Red
8Black
4Red
3Black
HA3
HB3
+5V
0V
5
6
20
16
9Black
9White
6Red
1Black
HA2
HB2
+5V
0V
HA3
HB3
+5V
0V
HA2
HB2
+5V
0V
#2
HA3
HB3
+5V
0V
#3
Recommended wire material
A66L-0001-0286(#20AWG×6+#24AWG×3 pairs)
Recommended connector
A02B-0120-K303including the following connector and case
(ConnectorFI40-2015S(Hirose Electric Co., Ltd.))
(Case FI40-20-CV5(Hirose Electric Co., Ltd.))
Recommended cables
A02B-0120-K841 (7m)(for connecting three manual pulse generators)
A02B-0120-K848 (7m)(for connecting two manual pulse generators)
A02B-0120-K847 (7m)(for connecting one manual pulse generator)
(These cables do not include the wire shown in the above figure.)
Manual pulse generator #2
(
M3screw terminal
Manual pulse generator #3
(
M3screw terminal
)

Contents Summary of Machine Operator's Panel Interface Unit (with 3-MPG interfaces) A-73282E/01 Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) No.TMN98/068E Date 1998.May.6 General Manager of Hardware Laboratory Machine Operator's Panel Interface Unit (with 3-MPG interfaces) 1. Communicate this report to: ○ Your information ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON Machine tool builder Sales agen
  • Page 2Machine Operator's Panel Interface Unit (with 3 MPG interfaces) Connection Manual -Item- 1. OVERVIEW 2. SPECIFICATION No. 3. CONNECTION 3.1 System Configuration 3.2 Signal Assignment 3.3 Interface for MPG 3.4 PMC Addresses 3.5 Dimension Diagram (Including Connector Locations) 4. Other notices 4.1 Ad
  • Page 3.OVERVIEW 1. The machine operator's panel interface unit with 3-MPG interfaces has been newly released. This manual describes the 3-MPG interfaces only. The other interfaces are identical to the existing unit. .SPECIFICATION No. 2. Specification note A16B-2201-0110 Existing unit :with one MPG interf
  • Page 43-2.Signal Assignment Connector pin signal assignment JA3(Connector on the manual pulse generator) 10 20 +5V 9 +5V 19 8 18 +5V 7 17 6 HB3 16 0V 5 HA3 15 4 HB2 14 0V 3 HA2 13 2 HB1 12 0V 1 HA1 11 Reference(The Other MG interface connectors) CA40 CNB1 14 DI37 01 +5V 01 LM 05 EON 09 HA1 08 DI31 15 0V 0
  • Page 53-3.Interface for MPG Machine operator's panel Interface unit Manual pulse generators JA3 Manual pulse generator #1 01 HA1 11 (M3screw terminal) 02 HB1 12 0V +5V 0V HA1 HB1 03 HA2 13 04 HB2 14 0V Manual pulse generator #2 05 HA3 15 (M3screw terminal) 06 HB3 16 0V +5V 0V HA2 HB2 07 17 Manual pulse ge
  • Page 6Scope in which PMC 3-4.PMC Addresses addresses can be used PMC BIT NUMBER I/O Link allocation ADDRES 7 6 5 4 3 2 1 0 128/128 256/256 DI+00 FUSE DI+01 KY07 KY06 KY05 KY04 KY03 KY02 KY01 KY00 DI+02 KY17 KY16 KY15 KY14 KY13 KY12 KY11 KY10 DI+03 KY27 KY26 KY25 KY24 KY23 KY22 KY21 KY20 DI+04 KY37 KY36 KY
  • Page 73-5.Dimension Diagram (Including Connector Locations) 4..Other notices 4-1. Address Allocation Allocation name of this unit is as follows. Allocation name PMC address Note 1) Remarks OC02I (16byte) DI+00~DI+15 1 MPG interface can be used OC03I (32byte) DI+00~DI+21 3 MPG interfaces can be used CM15I