3-3.Interface for MPG
EDIT.
SHEET
DRAW. NO. CUST.
TITLE
004/
DESCRIPTIONDESIG.DATE
A-73282E/01
JA3
Machine operator's panel
Interface unit
0V+5V HB1H
1
Manual pulse generator #1
M3screw terminal
Manual pulse generators
0V+5V HB
HA
0V+5V HB
HA
Cable connection
HA1
HB1
+5V
0V
1
2
9
12
7Red
7White
5Red
2Black
HA1
HB1
+5V
0V
Terminal block
Manual pulse
generators
HA1
HB1
+5V
0V
#1
Ground
plate
Shield
Cable Wire
01 HA1
02 HB1
03 HA2
04 HB2
05 HA3
06 HB3
07
08
09 +5V
10
11
12 0V
13
14 0V
15
16 0V
17
18 +5V
19
20 +5V
HA2
HB2
+5V
0V
3
4
18
14
8Red
8Black
4Red
3Black
HA3
HB3
+5V
0V
5
6
20
16
9Black
9White
6Red
1Black
HA2
HB2
+5V
0V
HA3
HB3
+5V
0V
HA2
HB2
+5V
0V
#2
HA3
HB3
+5V
0V
#3
Recommended wire material:
A66L-0001-0286(#20AWG×6+#24AWG×3 pairs)
Recommended connector:
A02B-0120-K303(including the following connector and case)
(Connector:FI40-2015S(Hirose Electric Co., Ltd.))
(Case :FI40-20-CV5(Hirose Electric Co., Ltd.))
Recommended cables:
A02B-0120-K841 (7m)(for connecting three manual pulse generators)
A02B-0120-K848 (7m)(for connecting two manual pulse generators)
A02B-0120-K847 (7m)(for connecting one manual pulse generator)
(These cables do not include the wire shown in the above figure.)
Manual pulse generator #2
M3screw terminal
Manual pulse generator #3
M3screw terminal