FANUC Series 16i/160i –L
Automatic leak check function
Specifications
A-78037E
00.03.17
K.Suzuki
Contents
Date
Design
M.Sato
Title
of
Drawing
Drawing
No
Page
2.2. Leak check screen
By using this screen, necessary parameters to use the Automatic leak check function can be set.
Moreover, the result of leak check can be confirmed.
Switching off Run signal (G222 #6:RUN) after setting the parameters on this screen can start
Automatic leak check function.
2.2.1. Displayed data
Following data are displayed on Leak check screen.
ON/OFF of leak check.
Leak judgement time.
Status.
The time required of leak check. (remainder time)
Result of Leak check.
(1) ON/OFF of leak check
The state of PRM No.15153#0 is displayed.
The setting is also possible.
0 : Automatic leak check function is disabled.
1 : Automatic leak check function is enabled
(2) Leak judgement time
Leak check judgment time (PRM.No15154) is displayed.
The setting is also possible.
(3) Status
The state while the Automatic leak check function operates is displayed.
The following states are displayed.
Evacuating
First gas pressure check
Second gas pressure check
Third gas pressure check
Fourth gas pressure check
(4) The time required of leak check.
The estimation time to complete the leak check is set at completion of evacuating and closing all
the valves.
This is a value that is subtracted the elapsed time from leak judgement time.
This display time is estimation, and the end schedule time is not guaranteed.
(5) Result of Leak check
Gas pressures1-4 (DGN954-957) during the Leak check are displayed.
These data are displayed only and can not be reset.
The data are displayed by 2 pressure units, Torr and kilo-Pascal (kPa).