1.DeviceNet FUNCTIONS SETTING B-64044EN/01
- 12 -
1.1 MASTER FUNCTION SETTING
The setting screen of the DeviceNet master function consists of the
BUS PARAMETRE screen and SLAVE PARAMETER screen.
To perform DeviceNet communication, set the bus parameter and
slave parameter.
The bus parameter is required to manage the whole DeviceNet
network. The slave parameter is required to communicate with each
of the slaves.
NOTE
Before setting the bus parameter, the following
conditions must be satisfied.
<1> The MDI mode or emergency stop state is
entered.
<2> NETWORK on the BUS PARAMETER screen
is OFFLINE.
Before setting the slave parameter, the following
conditions must be satisfied.
<1> The MDI mode or emergency stop state is
entered.
<2> NETWORK on the BUS PARAMETER screen
is OFFLINE.
<3> COMMUNICATE on the SLAVE
PARAMETER screen is ENABLE.
After setting the bus parameter and slave
parameter, be sure to power off the CNC. The
newly set parameters will be reflected to the
DeviceNet function the next time the CNC is
powered on.
Procedure
1 Press function key
SYSTEM
.
2 Soft key [DEVNET MASTER] appears. (When soft key [DevNet
MASTER] does not appear, press the continue key located at the
right end of soft keys several times.)
3 If you press soft key [DEVNET MASTER], the BUS
PARAMETER screen, SLAVE PARAMETER screen, NODE
INFORMATION screen, or MONITOR screen appears.
4 Press soft keys [BUS PARAM] and [SLAVE PARAM] and then
enter the parameters for the setting items of all setting screens
that appear.