B-64044EN/01 SETTING 1.DeviceNet FUNCTIONS
- 15 -
COMMON STATUS
This is status information found by the DeviceNet master. The
common status includes four types of status information: DeviceNet
MPU status 1, DeviceNet MPU status 2, master function status 1, and
slave communication states 1 to 8.
The common status occupies up to 14 bytes (size of the common
status), beginning with the common status address.
COMMON STATUS
COMMON STATUS
ADDRESS
DeviceNet MPU status 1 (2 bytes)
COMMON STATUS
ADDRESS + 2
DeviceNet MPU status 2 (2 bytes)
COMMON STATUS
ADDRESS + 4
Master function status 1 (2 bytes)
COMMON STATUS ADDRESS + 6 Slave communication state 1 (1 byte)
COMMON STATUS ADDRESS + 7 Slave communication state 2 (1 byte)
COMMON STATUS ADDRESS + 8 Slave communication state 3 (1 byte)
COMMON STATUS ADDRESS + 9 Slave communication state 4 (1 byte)
COMMON STATUS ADDRESS +
10
Slave communication state 5 (1 byte)
COMMON STATUS ADDRESS +
11
Slave communication state 6 (1 byte)
COMMON STATUS ADDRESS +
12
Slave communication state 7 (1 byte)
COMMON STATUS ADDRESS +
13
Slave communication state 8 (1 byte)
DeviceNet MPU status 1
Bit 0 : An error has occurred.
An error indicated by one of Bits 4 to 8 has
occurred.
Bit 1 : A master function error has occurred.
Bit 2, Bit 3 : Reserved.
Bit 4 : An error has occurred in the nonvolatile memory
on the DeviceNet daughter board.
Bit 5 : Busoff has been detected.
(Communication stopped because a
communication error occurred frequently.)
Bit 6 : MAC IDs are duplicate or a MAC ID error has
occurred.
Bit 7 : A network power failure has occurred.
Bit 8 : A transmit error has occurred.
Bit 9 to Bit15 : Reserved.
DeviceNet MPU status 2
Bit 0 : Online
Bit 1 : I/O communication is in progress.
Bit 2 : Reserved.
Bit 3 : Master function
Bit 4 : The DI/DO sizes of all slaves are zero.
Bit 5 to Bit 7 : Reserved.