1.DeviceNet FUNCTIONS SETTING B-64044EN/01
- 24 -
1.2 MAINTENANCE SCREEN OF THE DeviceNet MASTER
FUNCTION
The MAINTENANCE screen of the DeviceNet master function
consists of the NODE INFORMATION screen and MONITOR
screen.
The NODE INFORMATION screen is required to check the status of
the whole DeviceNet network. The MONITOR (FIRMWARE
INFORMATION) screen is required to check the state of the
DeviceNet master board. The MONITOR (ERROR RECORD)
screen is required to check the error detected by the DeviceNet master
board.
Procedure
1 Press function key
SYSTEM
.
2 Soft key [DEVNET MASTER] appears. (When soft key
[DEVNET MASTER] does not appear, press the continue key
located at the right end of soft keys several times.)
3 If you press soft key [DEVNET MASTER], the BUS
PARAMETER screen, SLAVE PARAMETER screen, NODE
INFORMATION screen, or MONITOR screen appears.
4 Press soft key [NODE INFORMATION] or [MONITOR] to
display the desired screen.