B-64044EN/01 SETTING 1.DeviceNet FUNCTIONS
- 29 -
ERROR, RECORD RECORD, ABNORMAL CODE, DETAIL CODE
An error detected by the firmware on the DeviceNet master board is
saved as an error log. An error log consists of eight records and
saved in sequence, starting with record 1. A record consists of an
abnormal code and detail code.
The error log is cleared to 0 by the clear operation or power-off of the
CNC.
DETAIL CODE ABNORMAL
CODE
Upper byte Lower byte
Description
0211H Local MAC ID 00H Duplicate MAC IDs
There is an MAC ID on the network that is the same as
the local MAC ID.
0340H 00H 00H Busoff detection
Communication stopped because a communication error
occurred frequently.
0341H 00H 00H Network power failure
Power for communication is not successfully supplied.
0342H 00H 00H Transmission error
A transmission timed out.
0344H 00H 00H Verification error
The DI/DO size set in the bus parameter differs from that
of the actual slave.
0345H 01H Slave MAC ID I/O communication error
An I/O communication error occurred on the slave
indicated by "Slave MAC ID."
CLEAR
When you press soft key [CLEAR], all records are cleared to 0.