1.DeviceNet FUNCTIONS SETTING B-64044EN/01
- 28 -
Display item
Item Description
MPU STATUS1 DeviceNet MPU status 1 is displayed.
This is the same as "DeviceNet MPU status 1"
included in the common status on the BUS
PARAMETER screen.
MPU STATUS2 DeviceNet MPU status 2 is displayed.
This is the same as "DeviceNet MPU status 2"
included in the common status on the BUS
PARAMETER screen.
MASTER
STATUS1
Master function status 1 is displayed.
This is the same as "Master function status 1"
included in the common status on the BUS
PARAMETER screen.
CAN RECV
COUNTER
The number of frames successfully received by the
LSI on the DeviceNet master board is displayed.
The display range is between 0 and 65535.
CAN SEND
COUNTER
The number of frames successfully sent by the LSI on
the DeviceNet master board is displayed.
The display range is between 0 and 65535.
CAN RECV
ERROR
COUNTER
The number of error frames received by the LSI on
the DeviceNet master board is displayed. This item
is set to 0 upon recovery from the reception error
state.
The display range is between 0 and 65535.
CAN SEND
ERROR
COUNTER
The number of error frames received by the LSI on
the DeviceNet master board is displayed. This item
is set to 0 upon recovery from the transmission error
state.
The display range is between 0 and 65535.
FIRMWARE
VERSION
The version information of the firmware on the
DeviceNet master board is displayed.
Example) 0102H : Version 1.02
RECORD N
(N=1-8)
Records (abnormal code and detail code) are
displayed.