1998/ 5/26
1.2.2Starting synchronization
Flexible synchronous control is started by setting flexible synchronous
control mode select signals (MTA, MTB, MTC, or MTD (G197.0,
G197.1, G197.2, or G197.3)) to 1. However, setting MTA, MTB, MTC,
or MTD to 1 during an automatic operation requires using an M code
specified in a parameter (No. 5670, 5672, 5674, or 5676). Up to three
of these M codes can be specified in one block by enabling the
one-block-to-multiple-M-code command (setting bit 7 of parameter No.
3404 to 1).
When MTA, MTB, MTC, or MTD is accepted, the flexible synchronous
control mode signal switching accepted signal (MFSYNA, MFSYNB,
MFSYNC, or MFSYND (F197.0, F197.1, F197.2, or F197.3)) is set to
1.
1.2.3Canceling synchronization
Flexible synchronous control is canceled by resetting flexible
synchronous control mode select signals (MTA, MTB, MTC, or MTD
(G197.0, G197.1, G197.2, or G197.3)) to 0.
When MTA, MTB, MTC, or MTD is accepted, the flexible synchronous
control mode signal switching accepted signal (MFSYNA, MFSYNB,
MFSYNC, or MFSYND (F197.0, F197.1, F197.2, or F197.3)) is reset
to 0.
1.2.4Retract function
Setting the RTRCT (G66.4) retract signal to 1 in the automatic
operation mode (MEM, MDI, etc.) or in the manual operation mode
(HNDL, JOG, etc.) can retract the axis specified in a parameter (bit 0
of parameter No. 7730) through a distance set in a parameter
(parameter No. 7741).
Note
1 A feedrate for retraction is set in a parameter (parameter No.
7740).
Feedrate overriding is disabled, however.
2 Feed hold is disabled during retraction.
3 If the retract signal is set to 1 during an automatic operation,
the automatic operation is stopped, and retraction is started.
Edit
4/30
Data Si
nature
Descri
tion
Flexible synchronous control Specifications
A-63540EN
Drawing No.
Page
2004/08/10 H.Minami
Whole revision E.Genma
04
05
2004/08/19
ddition of (5)
FANUC Series 16i/18i - MB/TB, 18i - MB5
Title