- Conditions to decide that Tool is in singular posture
When the angle between the tool and the singular posture is less than the
parameter No.11204, it is decided that the tool is in singular posture.
In the descriptions below, the description ‘when the tool is in singular…’ means
that ‘it is decided that the tool is in singular posture….’.
It is recommended that the following value or a little larger than that is set to the
parameter No.11204.
- Max(Maximum federate (parameter No.1420) or Rapid traverse(parameter
No.1432) of rotary axes) / 15000
- Movement in the case that Tool direction is compensated
In the case that the tool direction is compensated(Parameter RCM
(No.11200#0)=1),the rotary axes move to positions which are different from the
commanded positions, in real time. How the positions are determined is described
as follows :
1) In the case that the current position is singular and the position after
movement in real time is also singular.
: When the absolute position after movement in real time is not singular, the
two rotary axes don’t move.
: When the absolute position after movement in real time is singular, the
rotary axis closer to tool doesn’t move, but the rotary axis closer to workpiece
moves as commanded.
2) In the case that the current position is not singular and the position after
movement in real time is singular.
: The rotary axis closer to tool moves to the singular position, but the rotary
axis closer to workpiece doesn’t move.
3) In the case that the current position is singular and the position after
movement in real time is not singular.
: In order to position the tool to the correct direction, there are two pairs of
solutions of rotary axes angles within 0 – 360deg. One solution with which
the rotary axis closer to tool moves shorter is selected. And, the rotary axes
move to the positions of the selected solution.
4) In the case that the current position is not singular and the position after
movement in real time is not singular.
: In order to position the tool to the correct direction, there are two pairs of
solutions of rotary axes angles within 0 – 360deg. One solution with which
the rotary axes don’t pass the singular position is selected. And, the rotary
axes move to the positions of the selected solution.