A-79226E
Title
Draw
No.
Ed. Date Design Description
Date Jan.09.’04 Design. Apprv.
8/10
Page
FANUC Series 30i-MODEL A
One Touch Macro call
Abnormal end signal MCSP <Fn512.2>
[Classification] Output signal
[Function] This signal notifies the sequence of the macro call is terminated abnormally.
[Output condition] This signal is set to "1" in the following case:
- When the sequence is interrupted by reset or emergency stop or alarm.
This signal is set to "0" in the following case:
- When the mode change completion signal (MCFIN) becomes "1", and the
sequence is completed.
Call program confirmation signal MCEXx <Fn514.0—Fn515.7>
[Classification] Output signal
[Function] This signal notifies the program number called by the macro call.
The signal which corresponds to macro call start signal (MCSTx) is output.
[Output condition] This signal is set to "1" in the following case:
- While executing the sequence.
This signal is set to "0" in the following case:
- When the sequence is completed.
Signal Address
The list of the signal used by this function is shown as follows.
CNC→ PMC
#7 #6 #5 #4 #3 #2 #1 #0
Gn512
MCST8 MCST7 MCST6 MCST5 MCST4 MCST3 MCST2 MCST1
#7 #6 #5 #4 #3 #2 #1 #0
Gn513 MCST16 MCST15 MCST14 MCST13 MCST12 MCST11 MCST10 MCST9
#7 #6 #5 #4 #3 #2 #1 #0
Gn514
MCFIN
PMC→ CNC
#7 #6 #5 #4 #3 #2 #1 #0
Fn512
MCSP MCRQ MCEXE
#7 #6 #5 #4 #3 #2 #1 #0
Fn513
ZRNR DNCIR MD4R MD2R MD1R
#7 #6 #5 #4 #3 #2 #1 #0
Fn514
MCEX8 MCEX7 MCEX6 MCEX5 MCEX4 MCEX3 MCEX2 MCEX1
#7 #6 #5 #4 #3 #2 #1 #0
Fn515 MCEX16 MCEX15 MCEX14 MCEX13 MCEX12 MCEX11 MCEX10
MCEX9