A-79226E
Title
Draw
No.
Ed. Date Design Description
Date Jan.09.’04 Design. Apprv.
10/10
Page
FANUC Series 30i-MODEL A
One Touch Macro call
# 2 MC1 MTB dedicated folder 1 "//CNC_MEM/MTB1/" of the initial folders is:
0: Set as a search folder.
1: Not set as a search folder.
# 3 SYS The system folder "//CNC_MEM/SYSTEM/" of the initial folders is:
0: Set as a search folder.
1: Not set as a search folder.
Note
The folders set as the search targets are searched,
and the program found first is called. The search
order is as follows.
LIBRARY/, MTB2/, MTB1/, SYSTEM/
Alarm
Number
Message Description
DS0021
START ERROR(ONE TOUCH MACRO)
An One Touch Macro can not be start for the following
reasons:
(1) Feed hold signal *SP is”0”.
(2) During alarm status.
(3) Program restart signal SRN is “1”.
etc.
DS0059
SPECIFIED NUMBER NOT FOUND
The program of the specified O number is not
registered in the memory.
PS5306
MODE CHANGE ERROR
The mode is not changed correctly at start of
sequence.
The macro call start signal (MCSTx) has been asserted
without the reset state.