A-79226E
Title
Draw
No.
Ed. Date Design Description
Date Jan.09.’04 Design. Apprv.
9/10
Page
FANUC Series 30i-MODEL A
One Touch Macro call
Parameter
6095 The number of programs used by the macro call function
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 16
Specify the number of programs used by the macro call function.
For instance, when three is set, macro call start signal MCST1, MCST2, and
MCST3 is valid.
When “0” is specified, this function is invalid.
6095 The first O number of the program used by the macro call function
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 1 to 9999
Specify the first O number of the program used by the macro call function.
For instance, when 9000 is set, the relation between the MCSTx signal and
the started program is as follows.
MCST1 signal : O9000 is called
MCST2 signal : O9001 is called
: :
MCST16 signal : O9015 is called
#7 #6 #5 #4 #3 #2 #1 #0
3457 SYS MC1 MC2 LIB
[Input type] Parameter input
[Data type] Bit path
For programs called as listed below, the folders to be searched are set in
these parameters in advance.
- Subprogram call by M code / ASCII code / 2nd auxiliary function code
- Macro call by G code / M code / T code
- One Touch Macro call
# 0 LIB The common program folder "//CNC_MEM/USER/LIBRARY/" of the
initial folders is:
0: Set as a search folder.
1: Not set as a search folder.
# 1 MC2 MTB dedicated folder 2 "//CNC_MEM/MTB2/" of the initial folders is:
0: Set as a search folder.
1: Not set as a search folder.