4. Parameter
No. #7 #6 #5 #4 #3 #2 #1 #0
16960 RSRPT
Data type : Bit type
RSRPT Restart position of interrupted block is:
0 : interrupted position.
1 : head position that is the interrupted block.
16961 Minimum value of M code for mode start (mode 1)
16962 Maximum value of M code for mode start (mode 1)
16963 Minimum value of M code for mode start (mode 2)
16964 Maximum value of M code for mode start (mode 2)
16965 Minimum value of M code for mode start (mode 3)
16966 Maximum value of M code for mode start (mode 3)
16967 Minimum value of M code for mode start (mode 4)
16968 Maximum value of M code for mode start (mode 4)
16969 Minimum value of M code for mode start (mode 5)
16970 Maximum value of M code for mode start (mode 5)
16971 Minimum value of M code for mode start (mode 6)
16972 Maximum value of M code for mode start (mode 6)
16973 Minimum value of M code for mode start (mode 7)
16974 Maximum value of M code for mode start (mode 7)
16975 Minimum value of M code for mode start (mode 8)
16976 Maximum value of M code for mode start (mode 8)
16977 Minimum value of M code for mode start (mode 9)
16978 Maximum value of M code for mode start (mode 9)
16979 Minimum value of M code for mode start (mode 10)
16980 Maximum value of M code for mode start (mode 10)
Data type : 2-word
Valid data range : 0 - 99999999
Set value of M code for each machining mode starts (1 to 10). When commanded M code meets
the following conditions, CNC regards it as M code for mode start.
Minimum value ≤ Commanded M code ≤ Maximum value
But the following case, the mode setting is not valid.
1) Both minimum value and maximum value is set to “0”.
2) Minimum value > Maximum value
*2
Edit Date
Desig
Contents
Title
of
Drawing
Drawing
No.
FS16i/18i/160i/180i-PB
Program Auto Restart
S
ecifications
A-78518E
Page
6 / 6
Recog
nition
Newly designed Miyajima
Matsu
moto
01.06.01 01
01.09.21 02
Matsu
moto
Revision for mark *2
Miyajima