18/22
Design.
DateEd.
2002.05.06
SHEET
DRAW. No.
CUST.
TITLE
M.Niwa
Newly preparation
Spindle Learning Control Description
A-53866E-0425
01
7. Diagnosis related to Spindle EGB Control
Address Description Unit
716
Synchronous error between master and slave axis in Spindle
EGB Control (weight of error is slave axis side)
pulse
*Both αi SPM TYPE B and i series model B CNC are required for the display of synchronous error
on CNC diagnosis screen.
8. Spindle alarm and error related to Spindle Learning Control and Spindle EGB Control
8.1. Spindle alarm
Alarm No. Description Action
9124 : AL-124
(C4 on SPM LED)
Illegal learning period (No.4425) is
transferred from CNC. In other words,
constant speed command specified b
PMC is out of bounds.
Specify 25 to 6000 min
-1
constant
speed command by PMC to remain
learnin
period
No.4425
within 20 to
4800.
9125 : AL-125
(C4 on SPM LED)
Illegal maximum/minimum order of
dynamic characteristic compensation
Gx (No.4427, 4428) is set.
Reduce maximum/minimum order of
dynamic characteristic compensation
Gx (No.4427, 4428).
8.2. Spindle status error
Error No. Description Action
Er-33
(33 on SPM LED)
Hardware configuration is illegal. Change model A CNC into model B
Er-34
(34 on SPM LED)
Both of Spindle EGB Control and
Spindle FAD function are valid.
Disable Spindle FAD function when
Spindle EGB Control is used.