12. CUSTOMER'S BOARD MANIPULATION B-63322EN-2/01
- 56 -
Programmable input of dedicated customer's board parameters
•
••
• Overview
The values of the dedicated customer's board parameters can be
modified from programs.
•
••
• Command format
Format
G10L55; Selects the input mode for dedicated customer's board
parameters.
N_R_; Inputs parameters of a type other than type axis.
N_P_R_; Inputs parameters of type axis.
:
:
G11; Deselects input mode.
Descriptions of symbols
N_: Dedicated customer's board parameter number.
R_: Value to be set in a dedicated customer's board parameter.
P_: Axis number (to be specified when inputting a parameter of type
axis).
•
••
• Explanation
•
••
• Parameter setting (R_)
Specifies a value to be set in a dedicated customer's board parameter.
For a parameter of type real number, a decimal point is used with R_.
•
••
• Axis number (P_)
An axis number (P_) is used with a parameter of type axis to determine
the sequence in which the parameter is to appear on the CUSTOMER'S
BOARD (PARAMETER) screen.
For example, P2 specifies that the parameter is to appear in the second
place on the screen.
NOTE
1. Any NC command other than that listed above
cannot be used in the dedicated customer's board
parameter input mode.
2. In the dedicated customer's board parameter input
mode, the entry of a pocket calculator-type decimal
point is invalid for address R.
3. Specifying G11 triggers parameter transfer to the
customer's board side. The execution of the G11
block does not end until parameter transfer ends. If
a reset occurs before the end of the parameter
transfer, the execution of the G11 block is forced to
end, but the parameter transfer is continued.