B-63322EN-2/01 12. CUSTOMER'S BOARD MANIPULATION
- 71 -
Saving
Data saving is performed immediately before task No. 2 is started.
In every cycle, data between the addresses in each effective set is saved
sequentially (from set 1 to set 5).
•
••
• Examples
Effective set
Set 2 Start address 0x02400000 End address
0x02400003
Set 4 Start address 0x02400100 End address
0x0240010f
On the above assumption:
In every cycle, twenty bytes are saved in the following sequence:
0x02400000 to 0x02400003 (3 bytes) and then 0x02400100 to
0x0240010f (16 bytes)
NOTE
1. Satisfy: Start address < end address
2. Data saving places a heavy burden on the system.
If the saving of a large amount of data is specified,
the burden on the system becomes very heavy,
possibly leading to a system alarm condition.
Therefore, keep the data to be saved to the
minimum required amount.