B-63322EN-2/01 12. CUSTOMER'S BOARD MANIPULATION
- 77 -
NOTE
1. The traced data is clamped within the following
range:
-999999999 ≤ data ≤ 999999999
2. The following restrictions are imposed on the least
significant digit of the address according to the
access size:
One-byte length: No restriction
Two-byte length: Addresses 0, 2, 4, 6, 8, A, C, and
E
Four-byte length: Addresses 0, 2, 4, 8, and C
3. To output the traced memory contents to an
external unit, select the FS15i type. Selecting the
FS15B type will lead to a warning.
12.3 MANIPULATION PARAMETERS
#7 #6 #5 #4 #3 #2 #1 #0
2460 SCR PWW
[Input type] Parameter input
[Data type] Bit
#0 PWW Specifies whether to issue a warning if parameter transfer to the
customer's board has not been completed when an automatic operation
is started, as follows:
0: Issued
1: Not issued
#1 SCR Specifies whether to display the customer's board development support
function screen, as follows:
0: Not displayed
1: Displayed