B-63322EN-2/01 12. CUSTOMER'S BOARD MANIPULATION
- 69 -
•
••
• Specifying sets to be used
Up to five sets of addresses can be specified for saving.
After setting a desired set of start and end addresses, set the cursor to
"(0:ON 1:OFF)," using the cursor keys, and then press the
[ON:1] soft key.
If the start or end address is not specified normally, a warning is issued.
If the set selected by the cursor is not to be used, press soft key [OFF:0].
If the start or end address in a set is changed, the set is automatically
deselected.
•
••
• Saving start
After selecting data, press soft key [START].
The STATUS box changes to "START."
If no effective set has been set up, a warning is issued.
•
••
• Saving end
Press soft key [END].
The STATUS box changes to "END."
Data saving is stopped automatically when:
<1> The set, address, or mode specification is changed.
<2> In single mode, the save area is used up.
•
••
• MODE
This box is used to specify the method for using the save area.
There are two modes: Single and ring. The modes can be switched by
pressing the [BUFFER SINGLE] or [BUFFER RING] soft key.
The Mode box displays the currently selected mode.
See the following descriptions for explanations about the differences
between the single and ring modes.
•
••
• Presetting
Pressing the [POINTER PRESET] soft key sets both the top and
bottom addresses to the start address of the buffer area.
If saving is started by pressing the [START] soft key, presetting is
performed automatically before actual saving begins.
Presetting can also be performed during data saving.