12. CUSTOMER'S BOARD MANIPULATION B-63322EN-2/01
- 78 -
4601 File output format
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 to 1
This parameter specifies a format to be used in outputting data traced
by the waveform diagnosis function to an external input/output unit, as
follows:
0: FS15i format
1: FS15B format (old format)
NOTE
If the data to be output is traced memory contents,
be sure to reset this parameter to 0.
4730 Target board specification 1
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 to 1
This parameter specifies which board is to be subjected to specified-
memory tracing using trace data 1 of the waveform diagnosis function,
as follows:
0: CNC MAIN board
1: Customer's board
4731 Access size specification 1
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 to 4
This parameter specifies an access size for which specified-memory
tracing is to be performed using trace data 1 of the waveform diagnosis
function.
0: One-byte length (signed)
1: One-byte length (unsigned)
2: Two-byte length (signed)
3: Two-byte length (unsigned)
4: Four-byte length (signed)
NOTE
If the specified access size is invalid, a system
alarm condition may occur.