E.PARAMETERS APPENDIX B-66264EN/01
- 108 -
9124 Count of macro call using an M code (specification of 3 sets)
(2nd set)
9125 Start program number of macro call using an M code (specification of 3 sets)
(2nd set)
9126 Start M code of macro call using an M code (specification of 3 sets) (3rd set)
9127 Count of macro call using an M code (specification of 3 sets)
(3rd set)
9128 Start program number of macro call using an M code (specification of 3 sets)
(3rd set)
[Data type] Integer
[Valid data range] Start M code
(Nos. 9111, 9114, 9117, 9120, 9123, and 9126) : 1 to 99999999
Count
(Nos. 9112, 9115, 9118, 9121, 9124, and 9127) : 1 and up
The upper limit depends on the start M code and start program
number.
Start program number