B–63783EN/01
6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
237
Recommended connector for cable:
Housing : AMP 178289–8
Contact : AMP 1–175218–5
3 2 0V 1 +24V
6 5 0V 4 +24V
CA64 (Power source)
Recommended connector for cable:
Housing : AMP 1–178288–3 (3 pins type)
Contact : AMP 1–175218–5
CM67(ON/OFF,Program protect,ESP)
Recommended connector for cable:
Housing : AMP 178289–5
Contact : AMP 1–175218–5
CM65 (General–purpose DI)
Recommended connector for cable:
Hirose electric : HIF3BA–10D–2.54R
CM68 (General–purpose DI/DO
Recommended connector for cable:
Housing : AMP 178289–8
Contact : AMP 1–175218–5
A01 EON B01 EOFF
A02 COM1 B02 COM2
A03 Xm+1.4 B03 KEYCOM
A04 *ESP B04 ESPCM1
A05 TR1 B05 TR2
A01 B01
A02 B02 Xm+0.5
A03 Xm+0.1 B03 Xm+0.3
A04 +24V B04 Xm+0.4
A05 Xm+0.2 B05 Xm+0.0
A01 +24V B01 Xm+1.5
A02 Xm+1.6 B02 Xm+1.7
A03 Xm+2.0 B03 Xm+2.1
A04 Xm+2.2 B04 Xm+2.3
A05 Xm+2.4 B05 Xm+2.5
A06 TR3 B06 TR4
A07 TR5 B07 TR6
A08 Yn+5.3 B08 Yn+5.7
A09 Yn+6.3 B09 Yn+6.7
A10 DOCOM B10 0V
CM66 (General–purpose DI)
Recommended connector for cable:
Hirose electric : HIF3BA–10D–2.54R
CM69 (General–purpose DI/DO)
A01 B01
A02 B02 Xm+1.3
A03 Xm+0.7 B03 Xm+1.1
A04 +24V B04 Xm+1.2
A05 Xm+1.0 B05 Xm+0.6
A01 +24V B01 Xm+2.6
A02 Xm+2.7 B02 Xm+3.0
A03 Xm+3.1 B03 Xm+3.2
A04 Xm+3.3 B04 Xm+3.4
A05 Xm+3.5 B05 Xm+3.6
A06 Xm+3.7 B06 DICOM
A07 TR7 B07 TR8
A08 Yn+7.3 B08 Yn+7.4
A09 Yn+7.5 B09 Yn+7.6
A10 DOCOM B10 0V
CA65 (Power magnetic cabinet)
Recommended connector for cable:
Hirose electric : HIF3BA–20D–2.54R
A01 EON B01 EOFF
A02 COM1 B02 COM2
A03 *ESP B03 ESPCM1
A04 TR1 B04 TR2
A05 TR3 B05 TR4
A06 TR5 B06 TR6
A07 TR7 B07 TR8
A08 B08
A09 B09
A10 B10
6.12.3
Each Connections
6.12.3.1
Pin assignment