6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B–63783EN/01
62
Combinations of the units listed in Table 6.1 can be used as the machine
interface I/O.
The I/O unit for the FANUC I/O Link is installed separately from the
control unit, and the two units are mutually connected by a specialized
serial link (FANUC I/O Link). Multiple units can be placed in separate
locations as shown below. The machine operator’s panel that uses many
input/output signals can be easily interfaced especially by placing the
interface unit for machine operator’s panel and the operator’s panel
connection unit in the immediate vicinity of the machine operator’s panel.
The FANUC I/O Link enables high–speed data transfer between the
control unit and an external unit. The statuses of signals input from the
machine are transferred to the control unit at constant intervals. The
output signals from the control unit are sent to the external unit at constant
intervals. The FANUC I/O Link has more applications. For example, the
FANUC I/O Link is used to connect the FANUC Power Mate, which is
single–axis CNC, or the FANUC System F–Model D Mate (F–D Mate),
which is a cell controller. For details, see the subsequent description.
For details of the units which are not listed in Table 6.1, see the
corresponding operating manual.
Table 6.1 Types of machine interface I/O (for FANUC I/O Link)
Unit
Description Reference
Connector panel
I/O module
Distribution type I/O unit that handles the
input/output signals required by the pow-
er magnetics circuit; it has an interface
with a manual pulse generator.
Sec. 6.3
Operator’s panel
I/O module (for ma-
trix input)
Unit having an interface with a machine
operator’s panel; it has an interface with
a manual pulse generator.
Sec. 6.4
Operator’s panel
I/O module
Unit having an interface with a machine
operator’s panel that handles the input/
output signals required by the power
magnetics circuit; it has an interface with
a manual pulse generator.
Sec. 6.5
FANUC I/O Unit–
MODEL A
Modular I/O unit that supports a com-
bination of the input/output signals re-
quired by a power magnetics circuit.
Sec. 6.6
(B–61813E)
FANUC I/O Unit–
MODEL B
Distribution type I/O unit that supports a
combination of input/output signals re-
quired by a power magnetics circuit.
B–62163E
Machine operator’s
panel interface unit
Unit having an interface with a matrix of
key switches and LEDs on the machine
operator’s panel as well as an interface
with a manual pulse generator.
Sec. 6.7
Connection unit Unit having an interface with a machine. Sec. 6.8
6.1
GENERAL