B–64160EN/01
2. SETTING PARAMETERS FROM MDI
2
2
SETTING PARAMETERS FROM MDI
Follow the procedure below to set parameters.
(1) Place the NC in the MDI mode or the emergency stop state.
(2) Follow the substeps below to enable writing of parameters.
1. To display the setting screen, press the
OFFSET
SETTING
function key as
many times as required, or alternatively press the
OFFSET
SETTING
function
key once, then the [SETTING] section select soft key. The first
page of the setting screen appears.
2. Position the cursor on “PARAMETER WRITE” using the cursor
move keys.
SETTING (HANDY) O0001 N00010
PARAMETER WRITE = (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 0 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–3:CHANNEL NO.)
0
3. Press the [(OPRT)] soft key to display operation select soft keys.
>
MDI STOP *** *** *** 10:03:02
[NO.SRH] [ ON:1 ] [ OFF:0 ] [+INPUT] [INPUT]
← Soft key display
(section select)
4. To set “PARAMETER WRITE=” to 1, press the ON:1 soft key,
or alternatively enter 1 and press the INPUT soft key. From now
on, the parameters can be set. At the same time an alarm condi-
tion (P/S100 PARAMETER WRITE ENABLE) occurs in the
CNC.
(3) To display the parameter screen, press the
SYSTEM
function key as many
times as required, or alternatively press the
SYSTEM
function key once,
then the PARAM section select soft key.
(See “1. Displaying Parameters.”)
(4) Display the page containing the parameter you want to set, and position
the cursor on the parameter. (See “1. Displaying Parameters.”)
(5) Enter data, then press the [INPUT] soft key. The parameter indicated
by the cursor is set to the entered data.