4. DESCRIPTION OF PARAMETERS
B–64160EN/01
16
#7
RMS0135
#6 #5 #4 #3 #2
PRA
#1
ETX
#0
ASC
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ASC Communication code except NC data
0: ISO code
1: ASCII code
ETX End code for protocol A or extended protocol A
0: CR code in ASCII/ISO
1: ETX code in ASCII/ISO
NOTE
Use of ASCII/ISO is specified by ASC.
PRA Communication protocol
0: Protocol B
1: Protocol A
RMS State of remote/tape operation when protocol A is used
0: Always 0 is returned.
1: Contents of the change request of the remote/tape operation in the
SET command from the host is returned.
#7
MDN0138
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
MDN The DNC operation function by a memory card is:
0: Disabled.
1: Enabled. (A PCMCIA card attachment is required.)
NOTE
Use a PCMCIA card attachment suited to the CNC to secure
the memory card in the CNC.