1. GENERAL
INSTRUCTION
B-65202EN102
1
GENERAL
11 .
NOTES
Liquid cooling
FANUC’s built-in spindle motors are developed based on liquid cooling.
You will not obtain the rated output by air cooling. Use liquid cooling
system so that the rated output can be obtained.
Recommended coolant : IS0 VG2 (e.g. Idemitsu Super Multi 2)
Thermal switch
Do not cool the thermal switch locally. Over heat of motor may not be
detected.
Easy maintenance
Consider some structure for easy
maintenance.
The structure that stator, rotor and 4
c
sensor can be disassembled by ea hch unit
(spindle unit) is preferable.
Dry condition
A built-in spindle motor is an electric component. It may be damaged by
liquid like water
and oil. Therefore keep away from these. And also, keep
away from the outer air. To supply air into a spindle, use complete dry air,
if not water will condense on and in the motor. Refer to following “1.2
PROTECTION CLASS”.
Record the manufacturing number
Write down and remember the serial number on the lead wire of stator,
and the manufacturing number on the side of rotor, so that you can find
the manufacturing number of the motor that is used in the machine tool
when maintenance.
-42-