4. SENSOR
INSTRUCTION
B-65202EN102
Pin assignment
Connector JY5
Connector CN2
Over heat cable connection
@ Remove the blind plate on the hole for a cable gland from the
preamplifier box. Attach the cable gland on the plate for fix. Prepare
the cable gland by yourself.
Outer diameter of cable : 6 5.2 X!Z 0.3
Diameter of hole for cable gland fixation : @ 13mm
Recommended cable gland : Skintop ST-‘i by LAPP
@ Pull the over heat cable into the box and connect to the terminal TMl.
Torque for the screw tightening must be 3kgfcm. And then cramp the
cable by cable gland.
TMT&l&l
Connection
OHl, OH2
Connect the over heat cable (non-polarity)
G(SHLD)
Connect the shield wire of the over heat cable
@ Set the pins SELl, SEL2 to “B”. (Default “A”)
These pins are in the preamplifier as follows.
Signal cables from the sensor
Over heat cable
-64-