B-65202EN102
INSTRUCTION
1. GENERAL
Check resistance and insulation
Before and after assembling a spindle, check the resistance and insulation
of winding. And also, check these on regular intervals.
WARNING
Shut down the power supply and disconnect the leads which are connected tc
the amplifier before measuring to prevent an electric shock.
.
And insulate the terminals that are not used.
-Winding resistance
Use milli-ohm meter to measure the winding resistance according to the
following procedure. Insulate the terminals that are not used while
measuring. Refer to “ I .SPECIFICATIONS“ to know the connection type
(from A to E).
. Connection A
Measure the resistance between U-V, V-W, and W-U
* Connection B
Measure the resistance between U-X, V-Y. and W-Z.
* Connection C
Measure the resistance between Ul-Vl, UZ-V2, Vl-Wl, V2-
W2, Wl-Ul, and W2-U2.
* Connection D
Measure the resistance between U-X, V-Y, and W-Z
* Connection E
Measure the resistance between U-X, V-Y, W-Z, U-X2, V-Y2.
and W-Z2.
1 NOTE
Use milli-ohm meter to measure the resistance. General ohm meter
cnnnnt meastlre the resistance correctlv.
-insulation between winding and frame
Measure at SOOVDC
following.
- Over 1OOM Q
. 10 - 1OOM 0
al-10MQ
- Under 1M Q
with mega-ohm tester. And judge according to
Good
Deterioration has begun. It does not affect normal
use. But check the insulation on regular intervals.
Special care is required. Check the insulation on
regular intervals.
Damaged. Change the motor to the new one.
CAUTION
Measure the insulation in the minimum time. Continuous charge will affect the
-43