B-65202EN102
APPENDIX B. COOLING CONDITION
B
COOLING CONDITION
IC code
IC code means “International Cooling” and it indicates the cooling system
for a motor standardized in IEC34-6.
All FANUC’s built-in AC spindle motors are developed under IC9U7A7
and this means all motors require separated oil cooling system. We have
not recommended other cooling systems.
Actual calorie must be removed
You can calculate easily the actual calories that must be removed from the
built-in motor according to the formula below using data shown in
“ I .SPECIFICATIONS”. All data are got in the examinations based on
IEC34 using the recommended cooling jacket
Removed calories Q(W)=Coolant temperature rise(K) X Flow rate(!/min.)
X Specific heat(J/gK) X Density(g/cm3) X 1000+60
Capacity of cooler
Actual calories that must be removed can be calculated easily. But
required minimum capacity of cooler will be different from this, as there
are some heat diffusion to the environment and some heat production in
the other parts used in the cooling system and in the spindle. Therefore
considering safety,
Capacity of cooler=Calculated calories+Produced calories in other parts
(You can deduct the calories if you know the diffusion to the environment.)
is preferable
Coolant temperature setting
Physically, more calories can be removed if the coolant temperature is set
lower. But the lower coolant temperature will cause condensation in or on
the motor, and it will affect the motor life. Therefore, basically, set the
coolant temperature higher than the room temperature.
-85-