B-65202EN102
INSTRUCTION
4. SENSOR
43 .
SIGNAL CABLE LENGTH (ALLOWANCE)
Calculate the allowable signal cable length between the sensor and the
amplifier according to the formula below.
L
: Cable length [m]
m
: Number of wires connected to power supply and OV
A V: Allowable voltage drop (See table)
I : Power supply current of sensor [A] (See table)
R : Resistance of wire [R/m]
In the case of using recommended cable :
A66L-0001-0367
0.18mm2 = O.ll[R/m]
A66L-0001-0368 0.5mm2 = 0.0394[ R Im]
NOTE
HThe calculated cable length includes the cable length attached to the
sensor. Therefore cable length of K17 and K18 are shorter than the length
calculated here. Deduct the cable length attached to the sensor.
WTo minimize the noise affection, shorten the cable length as far as possible.
-69-