Page
Name
No.
FANUC Series 16i /18i /21i
TA/TB
Peck tapping cycle (G84 or G88)
Specifications
A-78549E
05213 Return or clearance in peck tapping cycle
[Data type] Word
[Unit of data]
Increment System IS-B IS-C IS-D Unit
Millimeter input 0.001 0.001 0.001 mm
Input input 0.0001 0.0001 0.0001 inch
[Valid data range] 0 to 32767
This parameter sets the return or clearance in the peck tapping cycle.
Set a value according to the setting of the parameter PCP(No.5200#5).
PCP=0 : Return value for the high-speed peck tapping cycle
PCP=1 : Cutting start distance for the peck tapping cycle (clearance value)
Note :
Unit of data for this parameter is always 0.001mm or 0.0001inch not dependent on
the Increment System.
Ed.
Date
Contents
Draw u
2004.06.09
15/16
Apprv.
Desig.
Desi
n
T. Kurokawa