01 04.07.22
Tokito Newly designed.
Drawing No.
A - 78778E
02 05.05.12 Tokito
Tilte
FS-16i/160i-LB
utomatic gap control axis retraction and
approaching function -- Specifications --
Edit
Date Design Recog. Contents Page
9 / 11
#2 modified.
If a set value is bigger than 20000, it is regarded as 20000.
15865 Z-axis position of starting X- and Y-axis
Data type : Word
Unit : 0.001mm
Range : 0~65535
Specify the Z-axis position of starting X- and Y-axis by a relative distance from
Z-axis position when this function is started.
If set value is zero, it is regarded as 30000.
System variable #6048 is assigned for this parameter.
15866 Deceleration position
Data type : Word
Unit : 0.001mm
Range : 0~65535
Specify the position where the Z-axis velocity is changed from approach
velocity to gap control velocity. This position is set by a relative distance from
Z-axis position when this function is started.
If set value is zero, it is regarded as 30000.
System variable #6049 is assigned for this parameter.
15867 Execution end position
Data type : Word
Unit : 0.001mm
Range : 0~65535
Specify a position where the movement of this function is regarded to be end.
This position is set by a relative distance from Z-axis position when this
function is started.
If set value is zero, it is regarded as zero.