A-90188E-01 APPENDIX SETTING METHOD FOR PMC-SB7
- 66 -
Setting item of PMC address for PMC-SB7
Item Description
BASIC
STATUS PMC
ADDRESS
Specify PMC address to set MODBUS status.
If the status information is not necessary, specify a
space character (SP).
The available PMC area is R and E.
AREA1-3
DATA PMC
ADDRESS
Specify the start address of the PMC area which is
used to exchange I/O data with MODBUS/TCP clients.
If you do not want to set this address., specify a space
character (SP).
The available PMC area is R, E and D.
DATA SIZE
(WORD)
Specify the I/O size to exchange I/O data with
MODBUS/TCP clients.
A unit is 16-bit word.
A range is the following.
- For a PMC address R or E : 0 – 4000 word
- For a PMC address D : 0 – 5000 word
CAUTION
Keep the following in mind when setting STATUS
ADDRESS and SIZE.
1 Make sure that it does not overlap with the input
data area of MODBUS/TCP Server function.
2 Make sure that it does not overlap with the input
data area of a ladder program.