3. DATA INPUT/OUTPUT
B–63325EN/03
274
1) Set input/output data.
See “Setting input/output data,” described earlier.
2) On the file list, position the cursor to the desired input file.
See “Displaying a file list,” described earlier.
3) Perform the necessary operation, according to the table below:
Input data Input operation
PROGRAM To input all the programs in the file
1) Enter EDIT mode.
2) Click the [PROG READ] soft key.
3) Click the [ALL] soft key.
To input a single program as is
1) Enter EDIT mode.
2) Click the [PROG READ] soft key.
3) Click the [1_PROGRAM] soft key.
4) Click the [NEW] soft key.
To input a program with its program number changed
1) Click EDIT mode.
2) Click the [PROG READ] soft key.
3) Click the [(PROG#)] soft key.
4) Key in the program number.
5) Click the [EXEC] soft key.
PARAMETER 1) Enter MDI mode.
2) Place the system in the emergency stop state.
3) Click the [DATA READ] soft key.
4) Click the [EXEC] soft key.
PITCH ERROR
TOOL COMPENSATION
WORK OFFSET
MACRO VAR.
T CODEOFFSET
FOFS
DOFS
1) Enter MDI mode.
2) Click the [DATA READ] soft key.
3) Click the [EXEC] soft key.
VOLUMETRIC
PERIODMAINTE1
PERIODMAINTE2
1) Enter EDIT mode.
2) Click the [DATA READ] soft key.
3) Click the [EXEC] soft key.
SYSTEMLOG
SYSTEMCONFIG
SRAM BACKUP
Cannot be input.
Inputting/outputting data
D Inputting data