5. DIGITAL SERVO
B–63325EN/03
320
On the FSSB setting screen, pressing rightmost soft key [+] displays the
following soft keys:
Fig. 5.2 (g)
To enter data, place the machine in MDI mode or the emergency stop state,
position the cursor to the point where a desired item is to be input, then
enter the desired data and press soft key [INPUT] (or the
INPUT
key on the
MDI panel).
When soft key [AUTO SET] is pressed after data entry, the corresponding
parameter is automatically set, provided the entered data is valid. If the
entered data contains an error, warning message “DATA IS
INCORRECT” is displayed.
To restore the previous value of a parameter if, for example, an entered
value is incorrect, press soft key [RESET].
When the power is turned on, values are read from the parameters and
displayed on the screen.
FSSB data setting
procedure