TITLE
Modification of FANUC FL-net Board
OPERATOR’S MANUAL
Addition of the following table to Page 75
Option parameters
Table 1-12 Option parameters
Item Description
OPTION1
Pa60
Bit parameters
Bit 0 : When setting 1, Cyclic data is byte-swapped.
Bit 1 : When setting 1, Word block data and
Transparent data of the message are
byte-swapped.
Bit 2 : When setting 1, Byte block data of the
message is byte-swapped.
Other bits are not used. Please set 0.
OPTION2
Pa61
OPTION 2 is not used at present.
Please set 0.
NOTE
The OPTION 1 parameter is available when Communication setting
software (654I series) is edition 04 or later and when FL-net control
software (6564 series / 656C series ) is edition 07 / 01 or later.
SHEET
11/17
DESCRIPTIONDESIGN DATE EDIT
01 Mutai First issue
B-63434EN/02-1
FANUC LTD.
02.05.20
DRAW.NO.