4. DESCRIPTION OF PARAMETERS
B–63980EN/01
46
1424 Manual rapid traverse rate for each axis
[Data type] 2–word axis
[Unit of data]
[Valid data range]
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B
Millimeter machine 1 mm/min 30 to 240000
Inch machine 0.1 inch/min 30 to 96000ă
Rotation axis 1 deg/min 30 to 240000
Set the rate of manual rapid traverse when the rapid traverse override is
100% for each axis.
NOTE
If 0 is set, the rate set in parameter 1420 is assumed.
1425 FL rate of the reference position return for each axis
[Data type] Word axis
[Unit of data]
[Valid data range]
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B
Millimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
Rotaion axis 1 deg/min 6 to 15000
Set feedrate (FL rate) after deceleration when the reference position return
is performed for each axis.
1426 External deceleration rate of cutting feed
[Data type] Word axis
[Unit of data]
[Valid data range]
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B
Millimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
Set the external deceleration rate of cutting feed.
1427 External deceleration rate of rapid traverse for each axis
[Data type] Word axis
[Unit of data]
[Valid data range]
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B
Millimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
Rotaion axis 1 deg/min 6 to 15000
Set the external deceleration rate of rapid traverse for each axis.