B–63980EN/01
4. DESCRIPTION OF PARAMETERS
89
3211 Keyword
[Data type] 2–word
When the value set as the password (set in parameter No.3210) is set in
this parameter, the locked state is released and the user can now modify
the password and the value set in bit 4 (NE9) of parameter No.3202.
NOTE
The value set in this parameter is not displayed. When the
power is turned off, this parameter is set to 0.
3216 Increment in sequence numbers inserted automatically
This parameter can be set at the “Setting screen”.
[Data type] Word
[Valid data range] 0 to 9999
Set the increment for sequence numbers for automatic sequence number
insertion (when SEQ, #5 of parameter 0000, is set to 1.)
#7
KEY3290
#6
MCM
#5 #4
IWZ
#3
WZO
#2
MCV
#1
GOF
#0
WOF
[Data type] Bit
WOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
GOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
MCV Macro variable setting by MDI key input is:
0 : Not disabled
1 : Disabled
WZO Setting a workpiece zero point offset value by MDI key input is:
0 : Not disabled
1 : Disabled
IWZ Setting a workpiece zero point offset value or workpiece shift value
(T–series) by MDI key input in the automatic operation activation or halt
state is:
0 : Not disabled
1 : Disabled
MCM The setting of custom macros by MDI key operation is:
0 : Enabled regardless of the mode.
1 : Enabled only in the MDI mode.
KEY For memory protection keys:
0 : The KEY1, KEY2, KEY3, and KEY4 signals are used.
1 : Only the KEY1 signal is used.