4. DESCRIPTION OF PARAMETERS
B–63980EN/01
86
#7
MCL
3203
#6
MER
#5
MIE
#4 #3 #2 #1 #0
[Data type] Bit
MIE After MDI operation is started, program editing during operation is:
0 : Enabled
1 : Disabled
MER When the last block of a program has been executed at single block
operation in the MDI mode, the executed block is:
0 : Not deleted
1 : Deleted
NOTE
When MER is set to 0, the program is deleted if the
end–of–record mark (%) is read and executed. (The mark %
is automatically inserted at the end of a program.)
MCL Whether a program prepared in the MDI mode is cleared by reset
0 : Not deleted
1 : deleted
#7
3204
#6
MKP
#5 #4 #3 #2
EXK
#1 #0
PAR
[Data type] Bit
PAR When a small keyboard is used, characters “[” and “]” are:
0 : Used as “[” and “]”.
1 : Used as “(” and “)”.
EXK The input character extension function is:
0 : Not used. ([C–EXT] soft key is displayed.)
1 : Used.
NOTE
The [C–EXT] soft key is used to select an operation on the
program screen. This soft key enables the entry of “(”, “)”,
and “@” using soft keys. This soft key is useful when using
the small MDI keyboard, which does not have the “(”, “)”, and
“@” keys.
MKP When M02, M30, or EOR(%) is executed during MDI operation, the
created MDI program is:
0 : Erased automatically.
1 : Not erased automatically.
NOTE
If the MER parameter (bit 6 of parameter No.3203) is 1,
executing the last block provides a choice of whether to
automatically erase a created program.