5.TOTAL CONNECTION DIAGRAMA-72562EN-027
- 21 -
(2)Cable specification
Applicable cable
Model
Heavy-duty
power cable
(Note 1)
Heat-resistant
cable (Note 2)
Screw Torque
SVPM*-5.5i
5.5mm
2
or S/2
or greater
5.5mm
2
or S/2
or greater
M5 2.0-2.5Nm
SVPM*-11i
8mm
2
or S/2 or
greater
8mm
2
or S/2 or
greater
M5 2.0-2.5Nm
SVPM*-15i
14 mm
2
or S/2
or greater
14 mm
2
or S/2
or greater
M5 2.0-2.5Nm
NOTE
1 Four-conductor polyvinyl heavy-duty power cable (JIS C3312)
(VCT : heat-resistant 60
°C)
2 Fire-retardant polyflex wire (heat-resistant 105
°C) or equivalent
to LMFC manufactured by The Furukawa Electric Co., Ltd.
3 The cross-section area of each cable is determined under the
following conditions:
(1) At SVPM rated output
(2) Environment temperature of cable : 30°C
(3) Number of harnesses
3 (No current flows through the ground wire during normal
operation.)
Select a required cable cross-section area according
to the user environment and conditions.
WARNING
Ensure that the power supply lines, power lines, and signal lines are
securely connected.
1.
A loose screw, loose connection, or the like will cause a motor
malfunction or overheating, or a ground fault.
2. Be careful of a loose screw and loose connection at the power
line and motor line. There is a possibility to cause the fire.