2.SPECIFICATIONSA-72562EN-027
- 7 -
ENVIRONMENTAL CONDITIONS
The servo amplifier beta i series must be installed in a sealed type cabinet to satisfy
the following environmental requirements:
(1) Ambient Temperature
Ambient temperature of the unit :
0 to 55°C (at operation)
-20 to 60°C (at keeping and transportation)
Ambient temperature outside of the cabinet : 0 to 45°C
(2) Humidity
Normally 90% RH or below, and condensation-free
(3) Vibration
In operation : Below 0.5G
(4) Atmosphere
No corrosive or conductive mists or drops should deposit directly on the
electronic circuits.
NOTE
Install the electronic circuits in an environment of contamination level 2
as defined in IEC 60664-1. To achieve contamination level 2 in a
severe environment where machine tools are used, electronic circuits
generally need to be installed in a cabinet complying with IP54.
(5) Notes on Installation
The beta i series servo amplifier is designed to be installed in the power magnetic
cabinet, with its heat sink projecting through the back of the cabinet. This carries
away the heat generated by the semi- conductors, thus preventing heat from
building up in the cabinet as much as possible. Therefore, note the following
when installing the amplifier.
(a) The heat sink must not be subjected to cutting fluid, oil mist, or cutting
chips. Otherwise, the cooling efficiency will be reduced so that the
characteristics of the amplifier cannot be guaranteed. This may also shorten
the life of the semiconductors. When installing the amplifier in a power
magnetics cabinet which is designed to draw in air, fit an air filter to the air
inlet. In addition, completely seal all cable holes and doors.
(b) No dust or cutting fluid must be able to enter through the exhaust port. The
flow of cooling air must not be obstructed.
(c) The amplifier must be installed where it can be easily inspected, removed,