2.SPECIFICATIONS A-72562EN-027
- 8 -
(d) Current lines and signal lines must be separated and noise must be
suppressed. See the section 5.3 and the connection manual for each CNC for
details.
(f) Each amplifier must be installed vertically.
(g) Servo amplifiers are to be arranged horizontally. When arranging servo
amplifiers vertically from necessity, note the following:
1) Ensure that cooling air from a lower amplifier does not blow directly
against the upper amplifier. Otherwise, radiation performance can
degrade and the rated output may not be satisfied.
2) Ensure that the flow of cooling air of a lower amplifier is not impeded.
(h) Maintenance areas must be reserved for each servo amplifier.
(6) De-rating
Consider derating as shown below, according to ambient temperatures.
SVPM all model
0
10 20 30 40 50 60 °C
Available Operating Time
mbient temperature
10
min.
5
min.
15
min.
TENTATIVE