A-79227E
Title
Draw
No.
Ed. Date Design Description
Date Jan.09.’04 Design. Apprv.
21/22
Page
FANUC Series 30i-MODEL A
External Data Input
6310 Setting for number addition to external operator messages
[Input type] Parameter input
[Data type]
Word machine group
[Unit of data]
[Valid data range] 0 to 4095
This parameter sets the number of messages to which message numbers are
to be prefixed in external operator message display.
When 0 is set, the same operation as when 100 is set is performed.
Example)
When 500 is set in this parameter, the messages of message numbers 0 to 499
are displayed together with their numbers on the screen. A message number
of 500 and up is not displayed on the screen, but only the corresponding
message is displayed on the screen.
NOTE
When these parameters are set, the power must be
turned off before operation is continued.