A-78656E/01 FANUC Series 16i/18i-TB Compound Machining Function
117/127
Nov.14.2001 Edition 1
8.2
Manual Parameter Setting
The parameter for turning mode(T-MOD) is set on the screen of
turning mode(T-DSP), and the same for milling mode(M-MOD,M-
DSP). The common parameter of both mode can be set on the screen
of both mode(T-DSP,M-DSP).
8.2.1
Optional Parameter
Procedure
1.
You set the parameter no.13002#0(TMD) or the parameter
no.13002#3 (MDD) to 1
2.
You confirm the display “T-DSP” in the lower right of the screen.
After that, you set the parameter no. 9900 to 9999 according to the
data sheet.
3.
You turn the power of CNC off and turn it on.
NOTE
In the compound machining function, the parameter of
the milling side (M-DSP) is automatically set according
to the parameter of the turning side (T-DSP).
Therefore, you must not set the parameter no. 9000 to
9999 of the milling side (M-DSP).
The optional parameters for the exclusive use of the
milling side are prepared on the turning side (T-DSP).