FANUC Series 16i/18i-TB Compound Machining Function A-78656E/01
Nov.14.2001 Edition 1
70/127
Deletion of tool life
management data
Programmed tool life management data for a group can be deleted.
Format Meaning of common
G10L3 P2 ;
P__ ;
P__ ;
P__ ;
G11 ;
M02(M30) ;
G10L3 P2 :deletion of group
P__ :Group number
G11 :End of deletion of group
Register of tool life
count type
Count types (time or frequency) can be registered for individual
groups.
Format Meaning of common
G10L3
( or
G10L3P1) ;
P__ L__ Q__ ;
T__ H__ D__ ;
P__ L__ Q__ ;
T__ H__ D__ ;
P__ L__ Q__ ;
T__ H__ D__ ;
G11 ;
M02(M30) ;
Q__ : Life count type (1:Frequency, 2:Time)
NOTE
1. The group number specified by P need not be
consecutive. All groups need not be specified.
2. Same plural T numbers can exist in specified data
repeatedly.
3. When Q command is omitted, a kind of life counter
depends on the setting of parameter 6800#2(LTM).
4. Whether tool life is to be indicated by time (minutes)
or by frequency, it is set by a parameter
No.6800#2(NTM).
Maximum value of tool life is as follows.
In case of minute:4300(minutes)
In case of frequency:9999(times)
5. The execution of G10 L3 command must be done in
milling mode.